Български English

Explosion Proof Range Electric Vibrators

We are engaged in offering good quality MVE-D Explosion Proof Range Electric Vibrators. The MVE-D explosion-proof vibrators have been designed for use in industrial processes in a potentially explosive atmosphere. The enclosure of the MVE-D vibrator is equipped with increased thickness and joints to prevent the transmission of an internal explosion to the surrounding area. The MVE-D series is characterized and enhanced by many different certifications, depending on the vibrator model.


MVE-D Explosion Proof Range; 2 POLES, 3000 - 3600 rpm

TYPE Mechanical Features Electric Features
Working moment (*) FC Weight Power Current Ia/In Cable      Glande
Kgcm Kg Kw A max (Y)
50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz Dust Gas
400V 460V (°C) T
MVE 800/3D 15.68 11.06 794 800 29.0 0.75 0.90 1.45 1.50 3.80 3.80 135 T4 M20
MVE 1300/3D 27.58 18.86 1355 1365 30.4 1.30 1.38 2.44 2.25 5.20 5.00 135 T4 M20
MVE 1600/3D 31.26 22.22 1601 1608 60.0 59.6 1.57 1.60 2.94 2.61 5.90 6.20 135 T4 M25
MVE 2000/3D 36.78 27.60 2027 1997 61.2 60.4 2.00 2.10 3.75 3.42 6.50 6.40 135 T4 M25
MVE 2300/3D 45.97 31.87 2302 2306 62.0 60.0 2.40 2.45 4.44 3.94 6.00 6.30 135 T4 M25
MVE 3200/3D 68.10 43.89 3252 3176 111.4 109.8 2.90 2.90 5.30 4.61 8.30 8.20 135 T4 M32
MVE 4000/3D 79.40 55.99 4033 4052 115.4 111.4 2.90 2.90 5.30 4.61 8.50 9.7 135 T4 M32

(*) Working moment = 2 x static moment

TYPE Dimensional Features
FIG. Size C M A B ØG Holes D E F H I L N
(mm) (mm) (mm)
50Hz-60Hz 50Hz-60Hz
MVE 800/3D A 50 335 65 120 170 17 4 209 240 28 103 195 205 166.5
MVE 1300/3D A 50 335 65 120 170 17 4 209 240 28 103 195 205 166.5
MVE 1600/3D A 60 478 105 140 190 17 4 234 267 31 124 238 234 222
MVE 2000/3D A 60 478 105 140 190 17 4 234 267 31 124 238 234 222
MVE 2300/3D A 63 478 105 140 190 22 4 234 267 31 124 238 234 222
MVE 3200/3D A 75 569 115 155 255 23.5 4 300 321 35 147 285 298 265
MVE 4000/3D A 75 569 115 155 255 23.5 4 300 321 35 147 285 298 265

MVE-D Explosion Proof Range - 4 POLES; 1500-1800 rpm

TYPE Mechanical Features Electric Features
Working moment (*) FC Weight Power  Current Ia/In Cable Glande
Kgcm Kg Kw Hp A max (Y)
50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz Dust Gas
400V 460V (°C) T
MVE 700/15D 56.83 39.36 714 712 35.8 0.62 0.73 0.83 0.98 1.32 1.41 3.00 3.20 135 T4 M20
MVE 1100/15D 88.67 56.83 1114 1028 44.2 39.2 0.65 0.78 0.87 1.05 1.50 1.70 3.80 3.80 135 T4 M20
MVE 1400/15D 108.57 76.72 1364 1388 68.2 66.6 0.90 1.10 1.21 1.48 1.71 1.78 4.00 4.00 135 T4 M25
MVE 1700/15D 137.31 91.98 1725 1664 70.2 67.8 1.15 1.30 1.54 1.74 2.16 2.09 4.70 4.50 135 T4 M25
MVE 2400/15D 187.69 137.36 2358 2485 76.4 70.4 1.60 1.90 2.15 2.55 3.00 3.20 4.90 4.90 135 T4 M25
MVE 2500/15D 203.53 135.65 2557 2454 98.4 92.4 1.80 2.00 2.41 2.68 3.40 3.40 6.00 6.10 135 T4 M25
MVE 3000/15D 248.66 169.75 3124 3071 105.9 95.4 1.90 2.30 2.55 3.08 3.70 3.80 6.50 6.60 135 T4 M25
MVE 3800/15D 306.69 204.74 3853 3704 138.4 126.8 2.20 2.60 2.95 3.49 4.12 4.15 6.80 6.80 135 T4 M32
MVE 3810/15D 306.69 204.74 3853 3704 140.5 128.9 2.20 2.60 2.95 3.49 4.12 4.15 6.80 6.80 135 T4 M32
MVE 4300/15D 343.22 240.95 4312 4359 142.8 132.0 2.50 3.00 3.35 4.02 5.70 5.80 7.00 7.20 135 T4 M32
MVE 5500/15D 437.39 303.74 5495 5495 200.6 198.4 3.60 3.45 4.83 4.63 6.50 6.60 7.10 7.00 135 T4 M32

(*) Working moment = 2 x static moment

TYPE Dimensional Features
FIG. Size C M A B ØG Holes D E F H I L N
(mm) (mm) (mm)
50Hz-60Hz 50Hz-60Hz
MVE 700/15D A 50 405 100 120 170 17 4 209 240 28 103 195 205 167
MVE 1100/15D A 50 467 405 131 100 120 170 17 4 209 240 28 103 195 205 167
MVE 1400/15D A 60 478 105 140 190 17 4 234 267 31 124 238 234 222
MVE 1700/15D A 63 478 105 140 190 22 4 234 267 31 124 238 234 222
MVE 2400/15D A 63 538 135 140 190 22 4 234 267 31 124 238 234 222
MVE 2500/15D A 70 526 115 155 225 22 4 274 309 35 140 255 264 236
MVE 3000/15D A 70 590 147 155 225 22 4 274 309 35 140 255 264 236
MVE 3800/15D A 75 619 140 155 255 23.5 4 300 321 35 147 285 304 265
MVE 3810/15D A 77 619 140 105 248 22 4 300 321 35 147 285 304 265
MVE 4300/15D A 75 619 140 155 255 23.5 4 300 321 35 147 285 304 265
MVE 5500/15D A 80 613 135 180 280 26 4 330 370 50 176 334 304 311

MVE-D Explosion Proof Range - 6 POLES , 1000 - 1200 rpm

TYPE Mechanical Features Electric Features
Working moment (*) FC Weight Power  Current Ia/In Cable Glande
Kgcm Kg Kw Hp A max (Y)
50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz Dust Gas
400V 460V (°C) T
MVE 500/1D 91.88 91.88 513 739 34.0 0.35 0.4 0.5 0.5 1.2 1.2 2.8 2.7 135 T4 M20
MVE 800/1D 137 109 767 873 70.2 67.8 0.7 0.8 0.9 1.0 1.3 1.3 2.8 2.8 135 T4 M25
MVE 1100/1D 188 137 1048 1104 87.8 81.4 0.8 0.8 1.0 1.1 1.4 1.3 3.2 3.1 135 T4 M25
MVE 1500/1D 285 197 1590 1580 92.0 84.9 1.1 1.3 1.5 1.7 2.1 2.0 3.3 3.3 135 T4 M25
MVE 1600/1D 300 203 1673 1636 108.4 97.4 1.1 1.3 1.5 1.7 2.8 3.2 3.7 3.6 135 T4 M26
MVE 2100/1D 373 249 2083 2000 122.7 108.9 1.5 1.8 2.0 2.4 3.0 3.0 4.3 4.4 135 T4 M26
MVE 2600/1D 467 307 2610 2466 157.0 139.9 2.0 2.1 2.6 2.8 3.6 3.4 4.8 4.8 135 T4 M32
MVE 3000/1D 540 380 3017 3053 163.8 146.2 2.2 2.4 3.0 3.2 4.5 4.3 5.0 5.0 135 T4 M32
MVE 3800/1D 680 437 3799 3517 224.0 203.2 2.5 3.0 3.4 4.0 4.7 4.9 5.9 6.0 135 T4 M32
MVE 4700/1D 838 584 4681 4697 239.2 220.8 3.2 3.9 4.3 5.2 6.5 6.0 5.5 5.7 135 T4 M32

(*) Working moment = 2 x static moment

TYPE Dimensional Features
FIG. Size C M A B ØG Holes D E F H I L N
(mm) (mm) (mm)
50Hz-60Hz 50Hz-60Hz
MVE 500/1D A 50 467 131 120 170 17 4 209 240 28 103 195 205 166.5
MVE 800/1D A 60 478 105 140 190 17 4 234 267 31 124 238 234 222
MVE 1100/1D A 63 538 135 140 190 22 4 234 267 31 124 238 234 222
MVE 1500/1D A 60 598 165 140 190 17 4 234 267 31 124 238 234 222
MVE 1600/1D A 70 590 147 155 225 22 4 274 309 35 140 255 264 236
MVE 2100/1D A 70 650 177 155 225 22 4 274 309 35 140 255 264 236
MVE 2600/1D A 75 739 200 155 255 23.5 4 300 321 35 147 285 304 265
MVE 3000/1D A 75 739 200 155 255 23.5 4 300 321 35 147 285 304 265
MVE 3800/1D A 80 693 175 180 280 26 4 330 370 50 176 334 304 311
MVE 4700/1D A 80 753 205 180 280 26 4 330 370 50 176 334 304 311

MVE-D Explosion Proof Range - 8 POLES, 750 - 900 rpm

TYPE Mechanical Features Electric Features
Working moment (*) FC Weight Power Current Ia/In Cable Glande
Kgcm Kg   Kw A max (Y)
50Hz-60Hz 50Hz 60Hz Kg         50Hz-60Hz Lb         50Hz-60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz Dust Gas
400V 460V (°C) T
MVE 250/075D 57.27 180 259 37.9 83.6 0.35 0.38 1.15 1.15 1.70 1.70 135 T4 M20
MVE 400/075D 84.02 264 380 43.4 95.7 0.35 0.38 1.15 1.15 1.90 1.90 135 T4 M20
MVE 650/075D 137.31 431 621 73.1 161.2 0.50 0.60 1.20 1.20 2.20 2.20 135 T4 M25
MVE 900/075D 187.72 589 849 79.4 175.0 0.65 0.78 1.23 1.29 2.50 2.50 135 T4 M25
MVE 1300/075D 299.6 941 1355 108.2 238.5 1.00 1.10 1.86 1.83 3.00 3.00 135 T4 M25
MVE 2100/075D 467.41 1468 2114 158.8 350.1 1.50 1.80 2.81 2.89 4.20 4.10 135 T4 M32
MVE 3100/075D 680.34 2137 3077 220.6 486.3 2.00 2.30 3.79 3.77 4.00 4.00 135 T4 M32
MVE 3800/075D 838.43 2633 3792 238.6 526.0 2.50 3.00 6.00 6.00 3.90 4.00 135 T4 M32

(*) Working moment = 2 x static moment

TYPE Dimensional Features
FIG. Size C M A B ØG Holes D E F H I L N
(mm) (mm) (mm)
50Hz-60Hz 50Hz-60Hz
MVE 250/075D A 50 405 100 120 170 17 4 209 240 28 103 195 205 167
MVE 400/075D A 50 467 131 120 170 17 4 209 240 28 103 195 205 167
MVE 650/075D A 60 478 105 140 190 17 4 234 267 31 124 238 234 222
MVE 900/075D A 63 538 135 140 190 22 4 234 267 31 124 238 234 222
MVE 1300/075D A 70 590 147 155 225 22 4 274 309 35 140 255 264 236
MVE 2100/075D A 75 739 200 155 255 23.5 4 300 321 35 147 285 304 265
MVE 3100/075D A 80 743 200 180 280 26 4 330 370 50 176 334 304 311
MVE 3800/075D A 80 743 200 180 280 26 4 330 370 50 176 334 304 311

Changed address